Steam vs hot water boilers in Chicago two-flats and greystones

If your building has radiators, it runs on either steam or hot water, and knowing which one you have changes how every repair is done.

EMBy Elmer Mulcahy, Heating Help Editor · 2026-11-02

How to tell which one you have

Look at the boiler. A steam boiler has a glass sight tube showing the water level and a pressure gauge that reads in very small numbers, usually 0 to 3 or 0 to 5 psi. A hot water boiler has a combined pressure and temperature gauge reading roughly 12 to 30 psi and a circulator pump on the piping.

At the radiators, steam systems have a small air vent on the side of each radiator, often shaped like a bullet. Hot water radiators have a small bleed valve near the top that opens with a key.

Basement of a Chicago greystone with a steam boiler, sight glass and insulated pipes running overhead

What steam needs

Steam is sensitive to a few settings. The pressure control should be set low, often under 2 psi. Main vents in the basement let air out of the steam mains quickly so steam reaches every radiator at once. Radiator vents need to be working, and one-pipe radiators need to tip slightly back toward the valve.

  • Check the water level in the sight glass every week or two in season.
  • Flush the low water cutoff as the manufacturer directs.
  • Replace dead main vents, which is often the cheapest big improvement.

What hot water needs

Hot water systems need the right pressure, an expansion tank that is not waterlogged, a working circulator and air out of the radiators. Bleeding the radiators at the start of the season and checking the pressure gauge solves most cold radiator complaints.

Replacing either kind

Steam buildings get a steam boiler sized to the connected radiation and piped with a correct header. Hot water buildings can choose between a cast iron boiler and a modulating condensing boiler, which can run very efficiently with cast iron radiators. In both cases the old boiler is almost always larger than the building now needs.

Answers

Quick questions

Can a steam building be converted to hot water?

It is possible but involved, and usually not worth it. A well tuned steam system can be comfortable and reasonable to run.

Why are the top floor radiators hotter than the bottom in my building?

In steam buildings that often points to main vents or pressure settings. In hot water buildings it can be air or balancing.