Chicago bungalow heating: ducts, radiators and the old octopus furnace

About a third of Chicago's single-family homes are brick bungalows, and they share a set of heating quirks that are easy to fix once you know them.

EMBy Elmer Mulcahy, Heating Help Editor · 2026-10-28

Many bungalows started with a gravity furnace

The bungalow belt was built mostly between 1910 and 1940. Many of those homes were heated by gravity furnaces, the big round units with ducts spreading out like an octopus. Warm air rose on its own through large ducts, no blower needed.

Most of those furnaces were replaced long ago, but the big round ducts often stayed. A modern furnace with a blower can push air through them, but the airflow is often uneven, the ducts may be wrapped in old insulation that should be tested before disturbing it, and the returns are usually too few.

Classic Chicago brick bungalow with a front bay window and a finished attic dormer under a snowy sky

Others were built with radiators

Plenty of bungalows were built with hot water or steam radiators instead. Those homes tend to be very comfortable in winter and have no ducts for central air. A boiler in good condition can run for decades, and a ductless mini-split or a small duct system in the attic is a common way to add cooling.

The attic problem

Many bungalows have a finished attic level with sloped ceilings and knee walls. That floor is usually the hottest in summer and the hardest to keep even in winter, because heat rises into it and escapes through the poorly insulated slopes. A single duct run or a radiator under a dormer rarely keeps up.

  • Insulating and air sealing the knee walls and slopes helps more than any equipment change.
  • A ductless mini-split head in the attic gives it its own heat and cooling.
  • Balancing the duct system or adding a return can help when ducts already reach the attic.

Replacing the furnace in a bungalow

Bungalows are often over-furnaced. A furnace sized decades ago for an uninsulated house is far too big after new windows and attic insulation. We size replacements by load calculation, which often lands on a smaller, quieter two-stage furnace that runs longer and heats more evenly.

Answers

Quick questions

Are old round ducts in my bungalow a problem?

Not always, but they often give uneven airflow, and old wrap on them may need testing before work. We check before recommending changes.

What is the best way to cool a bungalow with radiators?

A ductless mini-split for the attic and main floor, or a small duct high velocity system, depending on the layout.