Skip to content
(312) 854-8663Answered 24/7

Furnace pressure switch repair in Chicago, IL

A pressure switch code is one of the most common furnace faults, and the switch itself is not always the part that failed.

  • Answered 24/7
  • Furnaces
  • Chicago and suburbs
Technician connecting a digital manometer to a furnace pressure switch port with a thin rubber hose
Typical range$150 to $425Line open24/7

Furnaces

What is usually going on

The pressure switch is a small diaphragm switch that closes when the inducer creates enough draft. If it does not close, the furnace will not light. The switch can fail, but more often it is reporting a real problem: a cracked rubber hose, a plugged port, a blocked vent, a backed up condensate trap or a weak inducer.

We test the switch with a manometer against its rating, check the hose and ports, clear the trap and verify vent and intake are open. Replacing a switch without finding why it opened is how the same code comes back next week.

Signs you need this

  • Pressure switch open or closed fault code
  • Inducer runs, then the furnace stops without lighting
  • Gurgling or water in the pressure switch hose
  • The problem shows up on windy or snowy days
  • A clicking switch that does not stay closed

On the visit

What our tech checks and does

  1. Manometer test of draft against the switch rating
  2. Hose, ports and condensate trap
  3. Vent and intake terminations outside
  4. Inducer performance
  5. Switch replacement only if it is out of spec

In Chicago homes

Strong winds off the lake can cause nuisance pressure switch trips on some side wall vented furnaces. A different termination kit or relocating the vent away from a windy corner of the building can stop it.

Rows of furnace igniters, flame sensors and capacitors organized in bins inside a heating service van

Typical price in Chicago

$150 to $425

Switch, hose or trap repairs. Furnace prices depend on the part, the brand, how tight the furnace closet is and whether the call is after hours. The exact price is given after diagnosis and before any work starts.

All repair costs

Answers

Pressure Switch Repair questions

Can I bypass the pressure switch?

No. It is a safety device that keeps exhaust from spilling into the house. Bypassing it is dangerous.

Why does the code come back after a new switch?

Because the switch was reporting a vent, drain or inducer problem that was not fixed.

Does wind affect furnace venting?

It can on side wall vents. Repeated windy day trips can usually be solved with the vent termination.

Related

Services that often go with this one

Inducer Motor Repair

The draft inducer starts every cycle; when it fails, the furnace never lights.

See inducer motor repair

Furnace Venting & Flue Repair

Flue pipes, PVC vents, chimney liners and terminations, fixed to keep exhaust going out.

See furnace venting & flue repair

Furnace Short Cycling

Starts, stops and starts again: we find the trip, the sizing or the thermostat issue behind it.

See furnace short cycling

Furnace Blowing Cold Air

The blower runs but the air is cold: we find why the burners are not staying lit.

See furnace blowing cold air

Where we do this

Pressure Switch Repair across Chicagoland

We do this work every day in Chicago and the suburbs. A few of the places we cover:

No heat? Call now.

A person answers every call, day or night. Tell us what the furnace is doing and we will send the next truck.

(312) 854-8663
Call (312) 854-8663 · 24/7